Search
Account
ENG
Here you can find several accessories regarding SmartXide DOT®. Components and accessories, handpieces and tools add versatility and efficiency to our workstations. Browse here our list of accessories for your DEKA device.
HiScan DOT, with its 1,570,350 different combinations of parameters, is the most flexible scanner in the market. Power, distance between DOTs, DOT dwell time, SmartStack level, scanning methods, shape and size of the treatment area: these are all the parameters that can be individually adjusted to precisely tailor each treatment to the patient’s needs. With the introduction of the SmartStack technology, there a...
The straight closed handpiece focal 7” is suggested for the following applications: Dermatology, ENT and Gynaecology. The minimum spot size is 900mm.
The open handpiece, focal 7” is suggested for the following applications: Dermatology, ENT, and Gynaecology. The minimum spot size is 900mm. It can be used coupled with Miniscan Plus.
The straight closed terminal handpiece focal 2”, is suggested for the following applications: Dermatology (Blepharoplasty) and Gynaecology (Labioplasty).The minimum spot size is 150 mm.
The straight closed terminal handpiece focal 4”, with final spacer, is suggested for the following applications: ENT (Pharyngeal Surgery), Gynaecology (Vulvar Surgery) and General Surgery. The minimum spot size is 300 mm.
The straight closed terminal handpiece focal 4”, without final spacer, is suggested for the following applications: Dermatology, ENT, Gynaecology and General Surgery. The minimum spot size 300 mm.
The straight closed terminal handpiece 125mm focal 5”, with final spacer, is suggested for the following applications: ENT, Dermatology, Gynaecology and General Surgery. The minimum spot size is 400 mm.
The straight open terminal handpiece 125mm focal 5”, with final spacer, is suggested for the following applications: ENT, Dermatology, Gynaecology and General Surgery. It can be used coupled with Miniscan Plus The minimum spot size is 400 mm.
The open terminal handpiece focal 4”, with backstop, is suggested for ENT. The minimum spot size is 300 mm.
The straight open terminal handpiece focal 4”, with final spacer, is suggested for the following applications: ENT, Gynaecology and General Surgery. It can be used coupled with Miniscan Plus. The minimum spot size is 300 mm.
The straight closed terminal handpiece 125mm focal 5”, with backstop, is suggested for ENT. The minimum spot size is 400 mm.
The straight open terminal handpiece 125mm focal 2”, with backstop, is suggested for ENT. The minimum spot size is 200 mm.
The handpiece focal 2”, with straight and 120° tip, is suggested for Dentistry and ENT. The minimum spot size is 200 mm.
The handpiece focal 4”, with straight, 75°, 120° and open tips, is suggested for Dentistry and ENT. The minimum spot size is 400 mm.
The straight open terminal focusable handpiece, with spacer, is only available in black colour. It is suggested for ENT in oropharinx surgery. The handpiece integrates a Zoom of 180-400mm. The spot size has a range of 400 mm to 3 mm.
The straight open terminal focusable handpiece, with backstop, is only available in black colour. It is suggested for ENT in oropharinx surgery. The handpiece integrates a Zoom of 180-400mm. The spot size has a range of 400 mm to 3 mm.
Er:YAG laser beam is delivered through an articulated arm. This patented technology avoids all the inconveniences of transmission by an optical fibre or optically hollow wave-guide. These delivery systems for Er:YAG laser, are very fragile and change the power transmitted depending on the angle of curvature. Increased bend of the fibre reduces the power transmitted, and this causes two serious problems...
A set of 16 reusable tips: - 4 tips for cooled handpiece and 600 µm fibre - 4 tips for cooled handpieces and 300 µm or 200 µm fibres - 4 tips for non-cooled handpiece and 600 µm fibre - 4 tips for non-cooled handpieces and 300 µm or 200 µm fibres In each group, the 4 tips differ for the fibre exit angle which could be: straigh, 30°, 60° and 90°. Tips have to be linked to the distal part of the handpiece and are used to deliver the fibre end close to the tissue. This is important especially in order to reach all areas in the mouth or even the internal area of a tooth (in case of endodontic treatments).
All people, staing in the room where the laser is working, could be affected by laser radiation exposure. For this reason they must wear safety glasses. DEKA provides with every laser system specific laser safety eyewear which are appropriate for the laser wavelength, for the laser power and for the laser working modes. All glasses are compliant with European Community norm EN 207 which is stricter than the American norm ANSI Z 136...
Need more information about this product?